Introduces Freedom Heat Pumps as a distributor for Samsung EHS and Hitachi Yutaki heat pumps.
Explains Freedom Heat Pumps' process for project planning and installer support.
Guides homeowners on obtaining the end-user manual for product usage.
Details plate system installation for suspended floors, including materials and pipe placement.
Describes overlay panels for underfloor heating, including panel dimensions.
Explains screed systems where pipes are integrated into solid floor structures.
Describes brass manifolds, their features, and manufacturer.
Lists the range of controls offered, from basic to smart digital thermostats.
Details the specifications of the multilayer pipe used for underfloor heating.
Fields for capturing installation details required for warranty registration.
Instructions to take photos of the outdoor unit, control box, and cylinder for registration.
Provides advice on maintaining constant temperature and efficient operation for heat pumps.
Advises against using the Samsung controller and emphasizes avoiding power-offs in cold weather.
Explains how the system manages hot water cylinder temperature and prioritizes it over heating.
Details various symbols and their meanings on the controller display for system status.
Outlines the steps for annual maintenance, including filter cleaning and glycol testing.
Details checks for the hot water cylinder, immersion heater, and sensor.
Provides guidance on positioning, mounting, and drainage for the outdoor unit.
Explains where to site the indoor control box and its connections.
Shows the wiring connections for the pre-plumbed system, including components and power.
Details system flush, filling with water/glycol, and pressure checks for commissioning.
Step-by-step instructions to set the clock and adjust backlight settings on the controller.
Instructions for setting cylinder timers for consistent hot water heating, typically twice daily.
Details a built-in function to test wiring and components without tools.
Suggests installing a plate heat exchanger to reduce glycol usage in the system.
Shows wiring for heating and hot water systems, including power and communication cables.
Explains how to enter and configure 20 field settings for heating and hot water operation.
Guides on initiating heating mode and checking system temperatures.
Details how to start hot water heating, including setting cylinder temperature.
Explains error code 00, indicating no outdoor unit communication.
Describes troubleshooting the E911 alarm, likely related to the flow switch.
Explains why the unit may not start in cold weather and how to overcome it.
Explains error code E904 related to the hot water cylinder sensor.
Details communication errors between indoor and outdoor units.
Explains thermal fuse faults and potential workarounds.
Describes troubleshooting legionella failure and checking related settings.
Specifies pump requirements based on unit size and pipe separation distances.
Stresses the importance of a strainer for protecting the heat exchanger.
Explains the function of flow switches and meters, and their installation requirements.
Recommends propylene glycol mix (25%) for freeze protection and notes warranty implications.
Details requirements for dedicated heat pump cylinders, including sensor cable length and coil size.
Details the required power supplies for the outdoor unit and control box.
Specifies requirements for the communication cable between outdoor and indoor units.
Explains how thermostats, timers, and UFH manifolds provide run signals.
Shows the connection for the live wire from mains to the electric meter.
Shows the neutral connection from mains and out to the heat pump.
Illustrates system configuration for two heat pumps working together.
Shows system integration with other heat sources like boilers.
Details a hybrid system configuration with a combi boiler.
Illustrates a system setup for heating swimming pools.