EasyManua.ls Logo

Samsung HG24ED470AK - 4. Troubleshooting; 4-1. Previous Check

Samsung HG24ED470AK
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Troubleshooting
4-1. Previous Check
Check list for initial operation
AC Power Cord connected to the TV and the wall receptacle.•
Standby Power/IR Indicator LED is turned On.•
If Power/IR Indicator is not on check 10p power cable is connected and for correct Standby Voltage from SMPS to •
Main. Also check Jog Function Cable.
Power turned On with Jog Function or Remote.•
Power on command from main Board to SMPS.•
Power/IR Indicator Flashes.•
Panel Back Lights are turned On.•
If no Backlights, unplug AC Power Cord, unplug 10 pin connector to SMPS, plug in AC Power Cord, Back light should •
come on. Check Main Board operation for error.
Power/IR Indicator goes off. •
Picture or banner is displayed.•
If nothing is displayed, check the LVDS cable. -
ASSY PCB MAIN
DC VSS-LED PD BD
ASSY SPEAKER P (R/L)
ASSY BOARD P-JOG SWITCH & IR
CN202(to Power board)
1 DGND 6 SW_POWER_TO_SMPS
2 DGND 7 A13V_PW
3 A13V_PW 8 PWM_DIMMING1_OUT
4 DGND 9 A13V_PW
5 A13V_PW 10 UNDER_DRIVER
4-1
4. Troubleshooting

Table of Contents