S
Sabrina ElliottAug 21, 2025
What to do if the Timer LED is on but my Samsung Air Conditioner won't turn on?
- Ssophia21Aug 21, 2025
The timer is activated, and the unit is in ready mode. Cancel the timer operation for normal operation.
What to do if the Timer LED is on but my Samsung Air Conditioner won't turn on?
The timer is activated, and the unit is in ready mode. Cancel the timer operation for normal operation.
Why doesn't my Samsung MH035FPEA Air Conditioner cool when the room is hotter than the set temperature?
This can happen after a 3-minute delay when the compressor is re-operated, or when power is turned on.
What to do if the timer LED is lighting up but my Samsung MH035FPEA won't turn on?
If only the timer LED is lit and the air conditioner isn't operating, the unit should operate normally if the timer operation is cancelled.
What to do if my Samsung MH035FPEA Air Conditioner's compressor stops intermittently in COOL or DRY mode, and the fan speed decreases?
The compressor might be stopping intermittently, or the indoor fan speed might be decreasing, to prevent the inside/outside air from freezing, depending on the inside/outside air temperature.
Why does my Samsung Air Conditioner's compressor stop intermittently in DRY mode?
In DRY mode, the compressor operation is automatically controlled depending on the room temperature and humidity.
Why does the compressor and indoor fan stop intermittently in HEAT mode on my Samsung MH035FPEA Air Conditioner?
To protect the compressor from overheated air in HEAT mode, the compressor and indoor fan will stop intermittently if the room temperature exceeds the set temperature.
Why do the indoor and outdoor fans stop intermittently in HEAT mode on my Samsung MH035FPEA Air Conditioner?
In HEAT mode, the compressor operates in a reverse cycle to remove exterior ice. The indoor and outdoor fans do not operate intermittently for within 20% of the total heater operation.
Why is the compressor of the outdoor unit operating when my Samsung MH035FPEA is turned off in HEAT mode?
When the unit is turned off while de-ice is activated, the compressor continues operation for up to 12 minutes (maximum) until the deice is completed.
What to do if my Samsung MH035FPEA Air Conditioner indoor and outdoor units do not operate properly?
Check the terminals to ensure the indoor and outdoor units are properly linked by the same number of cables and that the connecting position on the terminal is correct.
Why does my Samsung MH035FPEA compressor stop and indoor fan stop intermittently in HEAT mode?
The compressor and indoor fan might stop intermittently if the room temperature exceeds the set temperature. This is to protect the compressor from overheated air when in HEAT mode.
Type | Air conditioner indoor unit |
---|---|
Multi-split | - |
Product color | White |
Remotely operated | Yes |
Dehumidifying capacity | 1.9 l/h |
Air conditioner functions | Cooling, Dehumidifying, Heating |
Cooling capacity in watts (nominal) | 3500 W |
Heating capacity in watts (nominal) (Average heating season) | 3800 W |
Current | - A |
Power consumption (cooling) (min) | - W |
Hourly energy consumption (cooling) | - kWh |
Indoor unit type | Wall-mountable |
Indoor unit depth | 179 mm |
Indoor unit width | 890 mm |
Indoor unit height | 285 mm |
Indoor unit weight | 8500 g |
Indoor units quantity | 1 |
Cooling airflow (indoor unit) | 498 m³/h |
Heating airflow (indoor unit) | 528 m³/h |
Indoor unit noise level (high speed) | 42 dB |
Outdoor units quantity | 0 |