Deciding on Where to Install the Air Conditioner (Continued)
PREPARING THE INSTALLATION
E-
6
◆ MH068FXEA4 / MH080FXEA4◆ MH068FXEA4 / MH080FXEA4
1, 220-240, 50
Indoor unit Outdoor unit
Power supply
Ø, V, Hz
✴✴23/26/35/52✴✴
MH068FXEA4
MH080FXEA4
✴✴23/26/35✴✴
✴✴52✴✴
Liquid
1/4”
1/4”
Gas
3/8”
1/2”
Unit
Outside diameter
◗ Piping outside diameter
◗ Piping length and the height
Dimension
Composition
1 Room max
length
25 m
A, B, C, D
2 Room total max
length
30 m
A+ B
3 Room total max
length
45 m
A + B + C
4 Room total max
length
70 m
A + B + C + D
Max height between
indoor units
3 m
(h)
Max height between
indoor unit & outdoor unit
15 m
(H)
160 mm
or more
100 mm
or more
200 mm
or more
300 mm
minimum
600 mm
minimum
600 mm
minimum
300 mm
minimum
Main power switch
AB CD
❊ The split type, 1-way cassette, duct type indoor units can be installed together.
(h) (H)
MH026FPEA IM_E_20238 1/24/05 5:25 PM Page 6