EasyManua.ls Logo

Samsung MH060FXEA3B - User Manual

Samsung MH060FXEA3B
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
THE FEATURE OF PRODUCTAIR CONDITIONER
Multi Inverter(Free Joint Multi) Series
– Variable Indoor Unit Combination(Free Joint Multi)
– Multi Inverter(Free Joint Multi) Series delivers
comfort to 2~4 rooms with a Single Outdoor Unit
– Smart & Low noise outdoor units in any condition.
Energy Saving
– High Efficiency DC inverter and BLDC Comp.
– Smart Inverter Control algorithm.
TBR Sine-Wave Compressor & Sine Wave Controller.
Convenient Installation
– 485 non Polarity / Auto addressing
– Easy checking system condition by 7-segment
Various Indoor Unit
– Vivace, MSP duct, Console, 1 way, Slim duct,
Mini 4 way, Neo Forte, MB
Space Saving & Environmental Friendly
– Compact & Light Outdoor Unit
– Slim and Quiet Indoor Units
SERVICE
Manual
Refer to the service manual in the GSPN(see the rear cover) for the more information.
FREE JOINT
MH020FVEA
MH023FVEA
MH026FVEA
MH035FVEA
MH052FVEA
MH020FNEA
MH026FNEA
MH035FNEA
MH052FNEA
MH023FBEA
MH026FBEA
MH035FBEA
MH052FBEA
MH026FKEA
MH035FKEA
MH030FMEA
MH035FMEA
MH052FMEA
MH023FEEA
MH026FEEA
MH035FEEA
MH052FUEA
MH026FJEA
MH035FJEA
FIXED
MH18VF1-09
MH19VF1-07
MH19VF1-12
FREE JOINT
MH040FXEA2B
MH050FXEA2B
MH060FXEA3B
MH070FXEA4B
MH080FXEA4B
FIXED
MH18VF1X
MH19VF1X
INDOOR UNIT OUTDOOR UNIT
MULTI AIR CONDITIONER

Other manuals for Samsung MH060FXEA3B

Questions and Answers

Summary

Samsung Multi Air Conditioner

Product Feature Overview

Highlights key features like Multi Inverter, Energy Saving, Convenient Installation, Various Indoor Units, and Space Saving.

Precautions and Safety

Installation and Operation Safety

Covers safe installation practices, power supply, and operation guidelines to prevent hazards.

Unit Handling and Disposal Guidelines

Details how to handle the unit safely and proper disposal methods for environmental reasons.

Product Specifications

Key Product Features and Benefits

Details the benefits and characteristics of the Multi Inverter series, including efficiency, installation, and design.

Detailed Technical Specifications

Provides comprehensive technical data for various indoor and outdoor units, including performance and dimensions.

Comparative Model Specifications

Compares specifications across different models, including design, weight, and noise levels for easy selection.

Accessory and Option Lists

Lists available accessories and optional components for indoor and outdoor units, with part numbers.

Alignment and Adjustments

Error Codes and Troubleshooting Procedures

Explains error codes displayed on indoor and outdoor units and provides troubleshooting steps for each.

Setting Unit Options and Configurations

Guides users through the process of setting optional features and configurations using the remote control.

Service: Disassembly and Reassembly

Required Tools for Service Operations

Lists essential tools required for disassembly and reassembly procedures of the air conditioner unit.

Outdoor Unit Disassembly Guide

Step-by-step instructions for disassembling the outdoor unit, including common work and component removal.

Parts Identification: Exploded Views & Lists

Indoor Unit Parts (MH020 FNEA;MH026 FNEA;MH035 FNEA;MH***VF1-**)

Illustrates the internal components of specific indoor units and provides a detailed parts list with code numbers.

Wiring Diagrams

Indoor Unit Wiring Schematics

Provides electrical wiring schematics for various indoor unit models, detailing connections and components.

Outdoor Unit Wiring Schematics

Illustrates the electrical wiring diagrams for outdoor units, showing system connections and power distribution.

Schematic Diagrams

Indoor Unit Circuit Diagrams

Presents detailed circuit diagrams for indoor units, outlining electronic components and their interconnections.

Outdoor Unit Circuit Diagrams

Shows the schematic diagrams for outdoor units, illustrating the electronic circuitry and functional blocks.

PCB Diagrams

Indoor Unit Main PCB Layouts

Diagrams showing the layout and component identification for indoor unit main PCBs, crucial for troubleshooting.

Outdoor Unit Main PCB Layouts

Illustrates the main PCB layout for outdoor units, identifying key components and connectors for service.

Troubleshooting Guide

Initial Checks and Operational Tests

Essential preliminary checks and operational tests to identify and resolve common air conditioner issues.

Fault Diagnosis by Symptom and Error Code

Systematic troubleshooting guide based on error codes and symptoms for diagnosing unit malfunctions.

PCB Inspection and Replacement Procedures

Procedures and precautions for inspecting and replacing components on the Printed Circuit Board (PCB).

Installation Reference

Optimal Installation Area Selection

Guidelines for choosing optimal locations for indoor, outdoor, and remote control units to ensure proper performance.

Pipe Connection and System Purging Procedures

Step-by-step instructions for connecting refrigerant pipes and purging air from the system for correct installation.

Refrigerant Refill and Adjustment Procedures

Procedures for refilling and adjusting refrigerant levels based on pipe length and system requirements.

Flare Nut Torque and Pump Down Method

Specifies correct torque values for flare nut connections and the "pump down" procedure for unit relocation or evaporator replacement.

Reference Information

Model Name Indexing Guide

A guide to understanding the model naming convention and its components for different air conditioner series.

Refrigerating Cycle Diagrams

Visual representation of the refrigerant flow and system components in various air conditioner models.

Technical Terms, Troubleshooting Q&A, and Refrigeration Basics

Explains technical terms, pressure/capacity units, troubleshooting Q&A, and basic refrigeration concepts.

Samsung MH060FXEA3B Specifications

General IconGeneral
Outdoor unit weight59000 g
Outdoor unit dimensions (WxDxH)880 x 310 x 798 mm
TypeAir conditioner outdoor unit
Hose length (max)45 m
Refrigerating mediumR410A
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)6800 W
Cooling capacity in watts (min)1500 W
Heating capacity in watts (max)7300 W
Heating energy efficiency (COP, W/W)4.04
Noise level (high speed)50 dB
Power requirements220-240V, 50Hz, 8.6A
Annual energy consumption800 kWh
Power consumption (cooling) (max)1880 W
Power consumption (cooling) (min)440 W
Power consumption (heating) (max)1830 W
Power consumption (heating) (min)350 W