EasyManua.ls Logo

Samsung MH18AP1(P2)-09 - Checking and Testing Operations

Samsung MH18AP1(P2)-09
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics36
To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly.
1. Review all the following elements in the installation:
Installation site strength
Piping connection tightness to detect any gas leakages
Connection wiring
Heat-resistant insulation of the piping
Drainage
Earthing wire connection
Correct operations (follow the steps below)
Room select switch in the indoor unit
2. Apply the power to the outdoor unit.
- Check the fuse (250V~, 5A) : The fuse is opened when the power line (L, N) is short.
6-2 Checking and Testing operations
A unit
A unit
B unit
C unit
ON
ON
OFF
OFF
ON
OFF
OFF
ON
Room select switch
1(#51) 2(#52)
ROOM NO
INDOOR UNIT
Room select switch
(A, B, C unit)
DB98_16045A(4)_1 1/29/04 4:56 PM Page 36