Connecting the Cables to the Outdoor Unit
I
NSTALLING THE
O
UTDOOR
U
NIT
2 Connect the assembly cable with the power cable such as figure.
➢ Each wire is labelled with the corresponding terminal number.
➢ Ensure the wire number of the indoor unit and the terminal
number of the outdoor unit.
1 Remove the terminal board cover on the side of the outdoor unit.
2 electric cables must be connected to the outdoor unit:
◆
The assembly cable connecting the indoor unit to the outdoor unit.
◆
The power cable connecting the auxiliary circuit breaker to the
outdoor unit.
3 Connect the earth wires to the earth terminals.
➢ Refer to the page 16 for further details on how to check
that earthing is correct.
4 Fix the cables with cable clamps near terminal blocks to protect the wire
connection to the terminals from force on the wire.
5 Replace the terminal board cover, carefully tightening the screw.
6 Connect the power cable to the auxiliary circuit breaker.
❊ The designs and shape are subject to
change according to the model.
The specification for cables :
Use
Main Power Supply 3-wire power cable
Indoor Power Supply 3-wire power cable
2-wire assembly cable
AWG
13 or fewer
16 or fewer
16 or fewer
Type Cross sectional area (mm
2
)
2.5 or more
1.5 or more
1.5 or more