E-8
Air Conditioner and Accessories
The following accessories are supplied with the air conditioner.
Accessories in the Outdoor Unit Case
3-wire
Power Cable
(option)
Rubber Leg
2-wire
Assembly Cable
(option)
Flare Nuts, 6.35mm
outer pipe diameter
PREPARING THE INSTALLATION
Flare Nuts, 9.52mm
outer pipe diameter
Drain Plug Transmitter power
cable
Installing and Connecting the Outdoor Unit Drain Hose
When using the air conditioner in the heating mode, ice may
accumulate. During de-icing, the condensed water must be drained
off safely. Consequently, you must install a drain hose on the outdoor
unit, following the instructions below.
1 Insert the drain plug into the drain hole on the underside of the outdoor unit.
2 Connect the drain hose to the drain plug.
3 Ensure that the drained water runs off correctly and safely.
Drain hole
Installation Manual
➢ The 3-wire power cable and the 2-wire assembly cable are optional. If these cables are not
supplied, use the standard cable approved by IEC standard.
3-wire
Power Cable
(option)
Rubber Leg
2-wire
Assembly Cable
(option)
Flare Nuts, 6.35mm
outer pipe diameter
Flare Nuts, 9.52mm
outer pipe diameter
Flare Bolt
(Nut 1/2”, Bolt 3/8”)
Drain Plug Transmitter power
cable
The specification for cables :
Use
3-wire power cable for main power supply
3-wire power cable for indoor power supply
2-wire assembly cable for communication
AWG
13 or fewer
16 or fewer
16 or fewer
Cross sectional area (mm
2
)
2.5 or more
1.5 or more
1.5 or more
Installation Manual
Energy Label
Energy Label
◆ MH18VP2X / MH19VP2X / MH052FXEA2
◆ MH068FXEA4 / MH080FXEA4
❋ Attach Energy Label to the outdoor unit properly when installing.