PREPARING THE INSTALLATION
E-7
ENGLISH
1, 220-240, 50
Indoor unit Outdoor unit
Power supply
Ø, V, Hz
✴✴23/26/35/52✴✴
MH068FXEA4
MH080FXEA4
✴✴
23/
26/35✴✴
✴✴52✴✴
Liquid
1/4
1/4
Gas
3/8
1/2
Unit
Outside diameter
Piping outside diameter
Piping length and the height
Dimension
Composition
1 Room max
length
25 m
A, B, C, D
2 Room total max
length
30 m
A+ B
3 Room total max
length
45 m
A + B + C
4 Room total max
length
70 m
A + B + C + D
Max height between
indoor units
3 m
(h)
Max height between
indoor unit & outdoor unit
15 m
(H)
160 mm
or more
100 mm
or more
200 mm
or more
300 mm
minimum
600 mm
minimum
600 mm
minimum
300 mm
minimum
Main power switch
(h) (H)
CD
AB
The split type, 1-way cassette, duct type indoor units can be installed together.
MH068FXEA4 / MH080FXEA4