EasyManua.ls Logo

Samsung MH18VP2X - Page 5

Samsung MH18VP2X
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E-5
ENGLISH
PREPARING THE INSTALLATION
160 mm
or more
200 mm
or more
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
100 mm
or more
300 mm
minimum
600 mm
minimum
600 mm
minimum
300 mm
minimum
A-unit
B-unit
Main power switch
(h)
(H)
MH18VP2X
Indoor unit Outdoor unit
Power supply
Ø, V, Hz
MH18VP2-09
MH18VP2X
1,220-240~,50
MH19VP2X
Indoor unit Outdoor unit
MH19VP2-07
MH19VP2-12
MH19VP2X
1,220-240~,50
Power supply
Ø, V, Hz
AB
Piping length and the height
Dimension
Composition
1 Room max
length
20 m
A, B
2 Room total max
length
40 m
A+ B
Max height between
indoor units
3m
(h)
Max height between
indoor unit & outdoor unit
15 m
(H)
MH18VP2-09
MH19VP2-07
MH19VP2-12
Liquid
1/4
Gas
3/8
Unit
Outer Diameter
Piping outside diameter