Troubleshooting
4-22 Samsung Electronics
4-2-4 ServiceAdjustment-YoumustperformCalibrationintheLatticePatternbeforeadjustingtheWhiteBalance.
■ ColorCalibration
Adjust spec.
※
※
Use other equipment only after comparing the result with that of the Master equipment.
Input mode Calibration Pattern
Lattice
<Table 1>
■ MethodofColorCalibration(Component)
1) Apply the 1080p Lattice (N0. 6) pattern signal to the Component IN 1 port
2) Press the Source key to switch to “Component1” mode
3) Enter Service mode
4) Select the “Calibration” menu
( Chess Pattern )