EasyManua.ls Logo

Samsung RC DHXGA Series User Manual

Samsung RC DHXGA Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RCDHXE
RCDHXGA
RCPHXEA
RCPHXGA
RCZHXEA
RCSHXEA
Air Conditioner
installation manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
100%
Recycled Paper
100%
Recycled Paper
100%
Recycled Paper
DB98-32793A(6)
IFSE P G RD
RC���DHXEA_IM_E_32793A(6).indd 29 2011-03-25 �� 11:01:10
Question and Answer IconNeed help?

Do you have a question about the Samsung RC DHXGA Series and is the answer not in the manual?

Samsung RC DHXGA Series Specifications

General IconGeneral
BrandSamsung
ModelRC DHXGA Series
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

General Information

Provides essential safety guidelines and general information for the installation and use of the air conditioner.

Installing the Unit

Power Supply Line, Fuse, or Circuit Breaker

Details on ensuring correct power supply connections, including fuses, circuit breakers, and grounding.

Preparation for Outdoor Unit Installation

A Type Outdoor Unit Preparation

Preparation details and diagrams for outdoor units of Type A, including model numbers.

B Type Outdoor Unit Preparation

Preparation details and diagrams for outdoor units of Type B, including model numbers.

C Type Outdoor Unit Preparation

Preparation details and diagrams for outdoor units of Type C, including model numbers.

Deciding on Where to Install the Outdoor Unit

Outdoor Unit Location Guidelines

Guidelines for selecting the optimal location for the outdoor unit, considering environmental factors and safety.

Single Unit Space Requirements

Details minimum clearance requirements for single outdoor units in various configurations.

Multiple Unit Space Requirements

Details minimum clearance requirements for multiple outdoor units in various configurations.

Outdoor Unit Installation

Outdoor Unit Support

Details on methods for supporting the outdoor unit, including wall mounting and rack installation.

Connecting the Cable

System Wiring Examples

Illustrates typical wiring diagrams for single and three-phase air conditioner systems.

Power Cable Specifications

Details power cable specifications for single and three-phase air conditioner units.

Indoor/Outdoor Connection Cable Specs

Details connection cable specifications and terminal block specs for indoor/outdoor units.

Power Cable and Connection Diagrams

Provides wiring diagrams for power cables and connection cords, including terminal connections.

Connecting the Refrigerant Pipe

Refrigerant Piping System

Details the refrigerant piping system, including maximum allowable lengths and height differences.

Temper Grade and Minimum Thickness of Refrigerant Pipe

Specifies temper grades and minimum thicknesses required for refrigerant pipes.

Connecting Up and Removing Air in the Circuit

Installing DPM

DPM Model Compatibility and Space Requirements

Lists compatible DPM models and specifies space requirements for installation.

DPM Operation and Setup

Covers connecting communication lines, DPM operations, and setting indoor unit quantity.

Cutting/Flaring the Pipes

Performing Leak Tests

Connecting the Drain Hose to the Outdoor Unit

Insulation

Using Stop Valve

Adding Refrigerant

Important Information Regulation Regarding Refrigerant

Important regulatory information concerning the safe use and handling of refrigerants.

How to Calculate the Quantity of Adding Refrigerant

Guide on calculating the correct quantity of additional refrigerant based on installation conditions.

Interface Module Installation (Optional)

Accessories for Interface Module

Lists and describes the accessories required for installing the interface module.

Pump Down Procedure

Relocation of the Air Conditioner

Details the pump down procedure specifically for relocating the air conditioner unit.

Checking Correct Grounding

Testing Operations

Power Supply and Indoor Unit Checks

Checks for correct power supply and indoor unit connections prior to testing.

Outdoor Unit PCB Test Mode

How to use outdoor unit PCB buttons (K1, K2) to run test modes (Heating, Cooling, Defrost).

Indoor Unit Air Treatment Check

Procedure to check indoor unit air treatment performance after 12 minutes of operation.

Resetting Outdoor Unit Power and Eco Mode

How to reset outdoor unit power supply and deactivate eco mode using the K3 button.

View Mode System State Information

Details on system state information accessible via the K4 switch in View Mode.

DIP Switch Option

Configuration options available through DIP switches, including auto/manual address and snow prevention.

Troubleshooting

Outdoor Unit Error Codes

Troubleshooting guide for the outdoor unit, detailing error codes and their meanings.

Related product manuals