EasyManua.ls Logo

Samsung RC DHXE Series User Manual

Samsung RC DHXE Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RCDHXE
RCDHXGA
RCPHXEA
RCPHXGA
RCZHXEA
RCSHXEA
Air Conditioner
installation manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
100%
Recycled Paper
100%
Recycled Paper
100%
Recycled Paper
DB98-32793A(6)
IFSE P G RD
RC���DHXEA_IM_E_32793A(6).indd 29 2011-03-25 �� 11:01:10
Question and Answer IconNeed help?

Do you have a question about the Samsung RC DHXE Series and is the answer not in the manual?

Samsung RC DHXE Series Specifications

General IconGeneral
RefrigerantR410A
Power Supply220-240V, 50Hz
Cooling Capacity12000 BTU/h
Heating Capacity12000 BTU/h
Noise Level (Outdoor)50 dB
Operating Temperature (Heating)-15°C to 24°C
Weight (Outdoor Unit)30 kg

Summary

Safety Precautions

General Safety Information

Important safety guidelines and warnings for installation and operation.

Outdoor Unit Installation Preparation

Outdoor Unit Installation

Location Selection and Clearances

Guidelines for choosing a suitable location and required clearances for the outdoor unit.

Mounting and Support

Instructions for fixing the unit with anchor bolts and using wall supports.

Electrical Connections

Power and Connection Cable Specs

Specifications for power and connection cables, including terminal block details.

Wiring Diagrams

Electrical diagrams showing power and connection cord wiring for various systems.

Power Terminal Connection

Procedures and torque specifications for connecting power terminals.

Refrigerant Pipe Installation

Piping System Requirements

Maximum allowable lengths and height differences for refrigerant pipes.

Pipe Material and Model Compatibility

Specifies pipe grade, thickness, and applicable outdoor unit models.

Air Circuit and Refrigerant Handling

Pipe Connection and Vacuum Procedure

Steps for connecting pipes, purging air, and performing leak tests.

DPM Installation Guide

Guidelines for DPM unit compatibility, installation, and communication.

Pipe Cutting and Flaring

Pipe Preparation and Tightening

Procedures for cutting, flaring pipes, and tightening fittings with torque specs.

Leak Testing and Drain Hose

Performing Leak Tests

Methods for detecting refrigerant leaks using nitrogen and R410A.

Drain Hose Installation

Instructions for connecting the drain hose to manage condensation.

Insulation and Stop Valve Operation

Pipe Insulation Requirements

Guidelines for insulating refrigerant pipes to prevent condensation.

Using Stop Valves

Procedures for opening and closing the stop valves correctly.

Adding Refrigerant

Refrigerant Charging and Calculation

Steps for charging, regulations, and calculating additional refrigerant quantity.

Interface Module and Pump Down

Interface Module Installation

Steps for installing the interface module for centralized control.

Pump Down Procedure

Procedure for removing refrigerant before unit relocation or evaporator replacement.

Grounding and Testing Operations

Grounding Installation

Instructions for selecting, installing, and connecting the grounding electrode and wire.

Testing Operations Overview

Procedures for checking power supply, indoor unit, and running outdoor unit test modes.

Testing Operations Details

View Mode Information Display

How to view system status information using the K4 switch.

DIP Switch Settings

Explanation of DIP switch options for configuration and control.

Troubleshooting Outdoor Unit Errors

Outdoor Unit Error Code List

Table listing error codes displayed on the outdoor unit PCB and their meanings.