Troubleshooting

If an error occurs during the operation, an LED flickers and the operation is stopped except the LED.
If you re-operate the air conditioner, it operates normally at first, then detect an error again.


On Flickering
Off
If you turn off the air conditioner when the LED is flickering, the LED is also turned off.
If you re-operate the air conditioner, it operates normally at first, then detect an error again.
Abnormal conditions
Indicators
Remarks
Concealed Type
Green Red
Standard Type
Power reset
X X
Error of temperature sensor
in the indoor unit (Open/Short)
X X X X
Displayed on
appropriate indoor unit
which is operating
Error of heat exchanger sensor
in the indoor unit
X X X
Displayed on
appropriate indoor unit
which is operating
EEPROM error
X X
EEPROM option error