7-3.
CD
section
7-3-1.
Focus
bias
adjustment
(1)
Turn
power
on
without
loading
a
disc.
(2)
Set
oscilloscope
voltage/DIV
to
DC
20mV.
(3)
Vref
to
GND
and
TP
2
(FE)
to
positive
terminal
on
the
oscilloscope.
(4)
Adjust
NVR1701
so
that
the
voltage
is
OmV
DC
on
the
oscilloscope.
7-3-2.
E.
F
balance
adjustment
=
(1)
Turn
power
on.
(2)
Set
oscilloscope
TIME/DIV
to
2mS.
(3)
Set
oscilloscope
voltage/DIV
to
0.5V.
(4)
Vref
to
GND
and
TP2
to
positive
terminal
on
the
oscilloscope.
(5)
Press
PLAY
with
loading
a
disc.
NVR
1701
(6)
Adjust
NVR1704
all
the
way
counterclockwise
(
Intermittent
sound).
(7)
Adjust
NVR1702
so
that
the
wave-form
is
equally
symmetrical
(
in
reference
to
GND).
(8)
Adjust
NVR1704
so
that
sound
comes
out
normally
(Nearly
mid-position
of
NVR1704).
A
~
|
ov
}
B
:
A=B
NVR
1702
VOLT/DIV
:
0.5
V
TIME/DIV
:
2mS
7-3-3.
Focus
gain
adjustment
(1)
Turn
power
on.
(2)
Vref
to
GND
and
TP1
(FE)
to
positive
terminal
on
the
oscilloscope.
(3)
Press
PLAY
after
loading
a
disc.
(4)
Adjust
NVR1703
so
that
the
wave-form
is
as
shown
in
the
figure.
(Normal
waveform)
(Low
focus
gain)
(High
focus
gain)
VOLT/DIV
:
0.1
V
VOLT/DIV
:
0.1
V
VOLT/DIV
:
0.1
V
TIME/DIV
:
2mS
TIME/DIV
:
2mS
TIME/DIV
:
2mS
7-3-4.
Traking
gain
adjustment
(1)
Turn
power
on.
(2)
Vref
to
GND
and
TP2
(TE)
to
positive
terminal
on
the
oscilloscope.
(3)
Press
PLAY
after
loading
a
disc.
(4)
Adjust
NVR1704
so
that
the
wave-form
is
as
shown
in
the
figure.
(Normal
wave-form)
(Low
focus
gain)
(High
focus
gain)
---0V
)
\
,
:
--0V
o]
pe
NVR
1704
VOLT/DIV
:
0.1
V
VOLT/DIV
:
0.1
V
VOLT/DIV
:
0.1
V
TIME/DIV
:
2mS
TIME/DIV
:
2mS
TIME/DIV
:
2mS
-