Samsung RCD-750 - Servicing Precautions; General Servicing Precautions; Insulation Checking Procedure

Samsung RCD-750
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-2.
Servicing
Precautions
CAUTION:
Before
servicing
Instruments
covered
by
this
service
manual
and
its
supplements,
read
and
follow
the
Safety
Precautions
section
of
this
manual.
Note:
If
unforseen
circument
create
conflict
between
the
following
servicing
precautions
and
any
of
the
safety
precautions,
always
follow
the
safety
precautions.
Remember:
Safety
First.
2-2-1.
General
Servicing
Precautions
(1)
a.
Always
unplug
the
instrument's
AC
power
cord
from
the
AC
power
source
before
(1)
removing
or
reinstalling
any
component,
circuit
board,
module
or
any
other
instrument
assembly,
(2)
disconnecting
any
instrument
electrical
plug
or
other
electrical
connection,
(3)
connecting
a
test
substitute
in
parallel
with
an
electrolytic
capacitor
in
the
instrument.
b.
Do
not
defeat
any
plug/socket
B+
voltage
interlocks
with
which
instruments
covered
by
this
service
manual
might
be
equipped.
c.
Do
not
apply
AC
power
to
this
instrument
and/or
any
of
its
electrical
assemblies
unless
all
solid-state
device
heat
sinks
are
correctly
installed.
d.
Always
connect
a
test
instrument's
ground
lead
to
the
instrument
chassis
ground
before
connecting
the
test
instrument
positive
lead.
Always
remove
the
test
instrument
ground
lead
last.
Note:
Refer
to
the
Safety
Precautions
section
ground
lead
last.
(2)
The
service
precautions
are
indicated
or
printed
on
the
cabinet,
chassis
or
components.
When
servicing,
follow
the
printed
or
indicated
service
precautions
and
service
materials.
(3
The
components
used
in
the
unit
have
a
specified
flame
resistance
and
dielectric
strength.
When
replacing
components,
use
components
which
have
the
same
ratings.
Components
identified
by
shading,
by
(x)
or
by
(
A\
)
in
the
circuit
diagram
are
important
for
safety
or
for
the
characteristics
of
the
unit.
Always
replace
them
with
the
exact
replacement
components.
(4)
An
insulation
tube
or
tape
is
sometimes
used
and
some
components
are
raised
above
the
printed
wiling
board
for
safety.
The
internal
wiring
is
sometimes
clamped
to
prevent
contact
with
heating
components.
Install
such
elements
as
they
were.
(5)
After
servicing,
always
check
that
the
removed
screws,
corponents,
and
wiring
have
been
installed
correctly
and
that
the
portion
around
the
serviced
part
has
not
been
damaged
and
so
on.
Further,
check
the
insulation
between
the
blades
of
the
attachment
plug
and
accessible
conductive
parts.
2-2-2.
Insulation
Checking
Procedure
Disconnect
the
attachment
plug
from
the
AC
outlet
and
turn
the
power
ON.
Connect
the
insulation
resistance
meter
(500V)
to
the
blades
of
the
attachment
plug.
The
insulation
resistance
between
each
blade
of
the
attachment
plug
and
accessible
conductive
parts
(see
note)
should
be
more
than
1
Megohm.
Note:
Accesible
conductive
parts
include
metal
panels,
input
terminals,
earphone
jacks,
etc.