70
TROUBLESHOOTING
6) If F Sensor has trouble
Bad contact of connector/ insert correctly
Are MAIN PCB
Connector CN30 and CN76
inserted correctly?
Is F Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN30#3(Red) and
REG1, HEAT SINK normal?
Is the input voltage of
IC01 MICOM #81 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Check the contact of PCB & Wire
Terminal correctly.
NO(0.6V > Measurement < 4.6V)
Check the iced-solder,
solder bridging, disturbed solder.
Replace the PCB
NO
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
** Measuring point of resistance value according to
Sensor **
F : CN30#3 CN76#1 measuring resistance value
** 0: Short trouble / ∞Ω: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #81,
CN30#3(Red) and REG1, HEAT SINK from
PCB typical Ground part are similar.
Check the measure on the SENSOR MARKING #1(R309)
due to the SMD MICOM
Checking method of F Sensor resistance
CN30#3(Red) CN76#1(Gray)
- Compare the temperature table after measurement.
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
F
Connector CN30#3(Red) to
REG1, HEAT SINK PCB typical Ground
Checking method of F Sensor voltage
- Measure the voltage of Sensor Check Point #1(IC01 MICOM #81) on
PCB or CN30#3(Red) REG1, HEAT SINK
- Compare the temperature table after measurement.
Measuring voltage of CN30#3(Red) REG1, HEAT SINK are as
Typical PCB Ground
REG1 Heater Sink
Start