EasyManua.ls Logo

Samsung RFG298AA - Page 72

Samsung RFG298AA
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
71
TROUBLESHOOTING
7) If F DEF Sensor has trouble
Bad contact of connector/ insert correctly
Are MAIN PCB
Connector CN30 and
CN76 insert correctly?
Is F DEF Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN30#4(Orange) and
REG1, HEAT SINK normal?
Is the input voltage of
IC01 MICOM #77 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Check the contact of PCB & Wire
Terminal correctly.
NO(0.6V > Measurement < 4.6V)
Check the iced-solder,
solder bridging, disturbed solder.
Replace the PCB
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
** Measuring point of resistance value according to
Sensor **
F-DEF : CN30#4 CN76#1 measuring resistance
value
** 0: Short trouble / ∞Ω: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #77,
CN30#4(Orange) and REG1, HEAT SINK from
PCB typical Ground part are similar.
Check the measure on the SENSOR MARKING #2(R310)
due to the SMD MICOM
Checking method of F DEF Sensor resistance
CN30#4(Orange) CN76#1(Gray)
- Compare the temperature table after measurement.
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
F DEF
Connector CN30#4(Orange) to
REG1, HEAT SINK PCB typical Ground
Checking method of F DEF Sensor voltage
- Measure the voltage of Sensor Check Point #2(IC01 MICOM
#77) on PCB or CN30#4(Orange) REG1, HEAT SINK
- Compare the temperature table after measurement.
Measuring voltage of CN30#4(Orange) REG1, HEAT SINK are
Typical PCB Ground
REG1, Heater Sink
Start
YES
YES
YES

Table of Contents

Other manuals for Samsung RFG298AA

Related product manuals