4. Specifications
Defrost Control From 24 to 32 hrs
Thermo-Bimetal 12
(off)/-5 (on)
Defrost Thermistor(502AT) 12
(off)
Maximum Current Leakage 0.25 mA
Maximum Ground Path Resistance 0.1 Ohm
Energy Consumption KWH/mo.
Ambient Temperature 20
32
Refrigerator, 1 7 1 7
Freezer,
-14 -25 -14 -25
Run Time,%
40 60
Refrigerant Charge (R134a) 220g
Compressor (Refer to Component Partlist)
Compressor oil Freol -15
Capillary tube(Dia, Length)
0.85, 3300mm
Dryer
Molecular Sieve XH-9
Clearance must be provided for air circulation
AT TOP 5cm
AT SIDES 0.25cm
AT REAR 5cm
RS24
**
, RS25
**
, RS26
**
, RS27
**
Main Board(Good) DA41-00139A
Main Board(Better&Best) DA41-00107A
Thermistor(Freezer) DA32-10109W
Thermistor(Freezer Evaporator) DA32-00006A
Thermistor(Refrigerator) DA32-10105U
Thermistor(Refrigerator Evaporator)
DA32-00006B
Thermistor(Ambient) DA32-10109V
Thermistor(CoolSelect Zone
TM
)
DA32-10109X
Thermistor(Ice-Maker)
DA32-10108B
Thermo-Bimetal DA47-10160E
Relay DA35-10013Q
Overload Relay DA34-10003D
Run Capacitor (12 ) 2501-001045
Fan-Motor(FRE) DA31-00020E
Fan-Motor(REF) DA31-00002S(Good)
Fan-Motor(REF) DA31-00020E(Better&Best)
Fan-Motor(Condenser) DA31-00020H
Thermal Fuse DA47-00095C
Fan
Fan
Fan
Fan
Fan
Fan
(Air inlet)
(Air inlet)
(Air inlet)
(Air inlet)
(Air inlet)
(Air inlet)
Heat exchanger
Heat exchanger
Heat exchangerHeat exchanger
Compressor
Dryer
C-Fan
Electric box
Sub-condenser
ELECTRICAL SPECIFICATIONS Freezer Refrigerator
NO LOAD PERFORMANCE
REFRIGERATION SYSTEM
INSTALLATION
MODELS
REPLACEMENT PARTS