No Error Items LED TROUBLE
1
I/M-SENSOR
Ice Maker Sensor Error- This can be an Electric wire cut, short-circuit,
contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
2
R-SENSOR
Refrigerator Compartment Sensor Error- This can be an Electric wire
cut, short-circuit, contact failure, or missing sensor. Cause is also a
temperature reading > 122°or < -58 ° F.
3
DEFROST
SENSOR OF R
ROOM
Ref. Defrost Sensor Error- This can be an Electric wire cut, short-circuit,
contact failure, or missing sensor. Cause is also a temperature reading >
122°or < -58 ° F.
4
R-FAN ERROR
This error indicates the Refrigerator Evap Fan is not spinning at the
correct RPM or the fan feedback line is open.
Samsung 'Refrigerator' Diagnostic Code Quick Guide
5
I/M FUNCTION
ERROR
This error indicates the Ice tray has not returned to level after an ice
harvest. The error is displayed after three failed attempts.
6
COOL SELECT
ZONE SENSOR
Cool Select Zone Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
7
R-DEFROSTING
ERROR
Refrigerator Room defrost heater- wire cut, short-circuit, contact failure,
missing sensor housing, or defective temperature fuse/bi-metal. Defrost
on for over 80 minutes
8
PANTRY-DAMPER
-
HEATER ERROR
Sensor system in Pantry Room errors
9
CR-SENSOR
4-Door
CR Compartment Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
9
PANTRY-SENSOR
ERROR
CR Compartment Sensor Error- This can be an Electric wire cut, short-
circuit, contact failure, or missing sensor. Cause is also a temperature
reading > 122°or < -58 ° F.
10
DEFROST
SENSOR OF CR
ROOM 4-Door
CR Compartment Defrost Sensor Error- This can be a wire cut, short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
DEFROST
CF Compartment Defrost Sensor Error
-
This can be a wire cut, short-
11
DEFROST
SENSOR OF CF
ROOM 4-Door
CF
Compartment
Defrost
Sensor
Error-
This
can
be
a
wire
cut
,
short-
circuit, contact failure, or missing sensor. This can also be caused by a
temperature reading > 122° or < -58 ° F.
12
CR-DEFROSTING
ERROR 4-Door
CR Compartment Defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
Defrost on for over 80 minutes
13
CF-DEFROSTING
ERROR 4-Door
CF Compartment defrosting heater- wire cut, short-circuit, contact
failure, missing sensor housing, or defective temperature fuse/bi-metal.
Defrost on for over 80 minutes
14
WATER HEATER
ERROR
Error is displayed when the water reservoir tank heater is open or shorted

Table of Contents