5
ITEM Specification
Model RS68N8941**
Components for defrosting
Defrosting Cycle
Initial defrosting cycle
(simultaneous defrosting of F and R)
6 hours
±
10 minutes
Defrosting cycle
of freezing component
12 to 77 hours
(varying dependent upon operation conditions)
Defrosting cycle of cold component
12 to 77 hours
(varying dependent upon operation conditions)
Idle duration
-
Defrosting
Sensor
F defrosting
Sensor
Type
Thermistor (DTN-C502)
Specification
5.0
at 25
R defrosting
Sensor
Type
Thermistor (DTN-C502)
Specification
5.0
at 25
Bimetal (F)
Type
Bimetal thermostat (BT-121-M)
Operating
temperature ()
On : 40
, Off : 60
Bimetal (R)
Type
-
Operating
temperature ()
-