40
TROUBLESHOOTING
ERROR DISPLAY
(Refer to Self-Diagnosis
Check List below)
※ Self-Diagnosis Check List
NO Defect Item Description
ERROR CODE
(Temp Display)
1 F-DEF ERROR Freezer Room Defrost Heater Error "1℃" LED LAMP
2 EXT - SENSOR External SENSOR Error "2℃" LED LAMP
3 R - SENSOR Fridge Room SENSOR Error "3℃" LED LAMP
4 F - DEF - SENSOR Freezer Defrost SENSOR Error "5℃" LED LAMP
5 F-FAN ERROR Freezer Room Fan Motor Error "7℃" LED LAMP
6 ICE MAKER ERROR
ICE MAKER Operation Error
ICE Sensor Error
ICE Maker Water Pipe Heater Error
'Ice Off" LED LAMP
7
COMP Run failure ERROR COMP Run failure ERROR
"Power Cool" LED LAMP
COMP IPM FAULT ERROR COMP IPM FAULT ERROR
COMP ABNORMAL CURRENT
DETECTION ERROR
COMP Location detection ERROR
COMP MOTOR RESTRICTION ERROR COMP MOTOR Bind ERROR
COMP Low Voltage ERROR COMP Low Voltage ERROR
COMP Over Voltage ERROR COMP Over Voltage ERROR