English - 23
CONNECTION & INSTALLATION
Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No Baud Rate (BPS) SW2-#5 SW2-#6
1 2,400 ON ON
2 4,800 ON OFF
3 9,600 OFF OFF
4 19,200 OFF ON
Communication Method Settings
Select a communication method for the camera.
Function ON OFF
SW2- #7 Transfer Mode Switch RS-422 (4Wire) RS-485 (2Wire)
Communication Response Settings
Select a communication response method for the camera and controller: Response or No Response.
Function ON OFF
SW2- #8 Response Mode Switch Response No Response
Termination Settings
To prevent the attenuation of communication signals between the camera and controller, the items at
the end of line must be set up with the termination settings.
Camera Input Position
SW2- #11 SW2- #12
Termination of Longest Path (RS-422)
ON ON
Termination of Longest Path (RS-485)
ON OFF
On the Path OFF OFF
Example of terminal setting
If using RS-422, SW2-#11: ON /SW2-#12: ON for camera 16
If using RS-485, SW2-#11: ON / SW2-#12: OFF for camera 16