6) Items for safety
Protecting device for overheating
- 1st protection device: Hardware cuts off when overheated
- 2nd protection device: Software cuts off when overheated
- 3rd protection device: Thermostat cuts off main power.
Safety device
- The fuser power is cut off when a front cover is opened
- A caution label has been added to the Fuser Unit to warn the customer of the “Hot Area”, so they can
use care when in that area. It can be easily seen when customer opens the rear cover.