System Overview
Samsung Electronics
Service Manual
3-17
Consumption Power
Length of Power Cord : 1830 50mm
Power Switch: Use
Feature
- Insulating Resistance: 100 or more (at DC 500V)
- Insulating revisiting pressure: Must be no problem within 1 min. (at 1,000V-LV / 1,500Vac-HV,10mA)
- Leaking Current: under 3.5mA
- Running Current: under 40A PEAK (AT 25 , COLD START)
under 60A PEAK (In other conditions)
- Rising Time: within 2Sec
- Falling Time: over 20ms
- Surge : Bi-Wave 3kV(2 ) - Normal, 6KV(12 ) - Common
Environment Condition
- Operating Temperature Range: 0 ~ 40
- Maintaining Temperature Range: -25 ~ 85
- Preserving Humidity Condition: 30% ~ 90% RH
- Operating Atmospheric Pressure Range: 1atm
EMI Requirement: CISPR, FCC, CE, MIC
Safety Requirement: IEC950 UL1950, CSA950, C-UL, Semko, CB, CCC(CCIB),GOST, EPA, Power Save
NO ITEM CH1(+5V) CH2(+24V) CH3(+24VS) System
1 Stand-By 0.2A 0.07A 0.07 A AVG : 100 Wh
2 PRINTING 1.0A 0.5A 1.0 A AVG 350 Wh
3 Sleep-Mode 0.2A 0.02A 0.03A AVG : 10 Wh