27Samsung Electronics
6-4 Fault Diagnosis of Major Parts
Indoor "Temp.Sensor"
Indoor "Heat ex. Sensor"
Outdoor "Temp.Sensor"
Outdoor "Deice Temp. Sensor"
Outdoor "Discharge
Temp.Sensor"
Outdoor "OLP Temp.Sensor"
Indoor Fan Motor
Outdoor Fan Motor
Stepping Motor
(UP/DOWN swing motor)
Stepping Motor
(FRONT GRILLE motor)
Measure resistance with a tester.
Normal
Abnormal , O open or short
Normal
Abnormal , O open or short
Measure the voltage between terminals (CN72) with a tester
Normal At ambient temperature (10°C ~ 30°C)
Abnormal
Measure the voltage between ground and signal wire of the fan motor
Normal
Abnormal Abnormal if voltage does not change from 0V to 5V.
Normal At ambient temperature (10°C ~ 30°C)
Abnormal , O open or short
Measure resistance between red wire and each terminal.
Normal Approx. 290 at ambient temperature (20°C ~30°C)
Abnormal , O open or short
Measure resistance between red wire and each terminal.
Normal Approx. 110 at ambient temperature (20°C ~30°C)
Abnormal , O open or short
DiagnosisPart
Ambient temperature 15°C20°C25°C30°C35°C40°C
Resistance of
14.68 12.09 10 8.31 6.94 5.83
thermistor[K]
Ambient temperature 0°C10°C20°C30°C40°C50°C
Resistance of
553 362 242 166 165 82
thermistor[K]
between Voltage[V]
Red, Blue 410±10% Main
Red, Yellow 325±10% Sub
between Voltage
Gray, Orange 0.5V~4.5V
Yellow, Orange 5V
between Resistance[]
Black, Red 275±10% Main
Black, Yellow 350±10% Sub