Installation
374
In case you want more information about the controllers and accessories, please refer to the Controller and
Accessory TDB on pvi.Samsung.com site or Global Partner Portal site.
DPM installation outdoor unit
Model
Diameter of L₁, a & b
pipe
Installation condition Amount of additional refrigerant charging
AC071RXADKG   
AC100RXAD*G
AC120RXAD*G
Ø9.52 
(L
1


AC140RXAD*G Ø9.52 


Optional: Installing DPM
DPM allowable Outdoor and indoor unit models
DPM allowable Outdoor and indoor unit models
Outdoor unit models
2 indoor units connection
Indoor unit
AC071RXADKG
AC035RN1DKG
AC035RNNDKG
AC035RNMDKG
AC035RNLDKG
AC035TNXDKG
AC035RNADKG

e.g. When you install the AC071RXADKG outdoor unit as DPM combination such as 2 indoor units connection,
only the combination on the table is available...
DPM allowable Outdoor and indoor unit models
Outdoor unit
2 IDUs connection 3 IDUs connection 4 IDUs connection
Indoor Unit Indoor Unit Indoor Unit
AC100RXAD*G AC052*N*DKG AC035*N*DKG -
AC120RXAD*G - AC052*N*DKG AC035*N*DKG
AC140RXAD*G AC071*N**KG AC052*N*DKG AC035*N*DKG
Installation of multiple indoor units should consist of units that have the same capacity.
e.g. When you install the AC100RXADKG outdoor unit as DPM combination such as 2 or 3 indoor units
connection, only the combination of two AC052*N*DKG or three AC035*N*DKG is available.