http://www.emc2000.co.kr
Report No.: 14EMC-RT-1203
EMC compliance Ltd. Page: 2 of 4
65, Sinwon-ro, Yeongtong-gu, Suwon, Kyunggi-do 443-390, Korea
82 31 336 9919 (Main) 0505 299 8311 (Fax)
1. Reference Documents
IEC 62262 and IEC 60068-2-75
Degrees of protection provided by enclosure for electrical equipment against external
mechanical impacts (IK code)
2. Test Performed
Degree of protection provided by enclosure for external impacts IK08
3. General Test Conditions
Tamb: 27 RH: 34 %
4. Test Conditions
According to standard IEC 62262 and IEC 60068-2-75
The verification of IK08 has been done positioning the enclosure on a rigid support.
5 impacts have been applied on each surface in sight with the enclosure.
For the test used Pendulum Hammer
IK08 (Characteristrics of impact test):
Energy: 5 Joule
Mass: 1.7 kg
High Δ h: 295 mm
5. Drop Zones:
The areas that were focused upon for this impact test are as follows: