6. Test Mode
• Driving Compartment Test
Pre-wash VALVE ON(0.3sec) ➔ OFF(0.3sec) ➔ COLD VALVE ON(0.3sec) ➔ [OFF(0.3sec) ➔
HOT VALVE ON (0.3sec) : OPTION ] ➔ OFF(0.3sec) ➔Rinse VALVE ON(0.3sec) ➔ OFF(0.3sec) ➔
Pump MOTOR ON(0.3sec) ➔ OFF(0.3sec) ➔ MOTOR RELAY1 ON(0.3sec) ➔ OFF(0.3sec) ➔
MOTOR RELAY2 ON(0.3sec) ➔ OFF(0.3sec) ➔ MOTOR RELAY2 ON(0.3sec) ➔ OFF(0.3sec) ➔
HEATER RELAY ON(0.3sec) ➔ OFF(0.3sec) ➔ DOOR OPEN (Function continues when door is closed)
2. THERMISTOR TEST MODE
A. Hold down “Delay Start” and Function keys simultaneously and then press POWER S/W on.
B. Display shows the inside temperature of Tub.
3. UNBALANCE TEST MODE
A. Hold down “Temp” and “Spin” keys simultaneously and then press POWER S/W ON.
B. Display shows ”Ut” or “Unbt” and the machine starts to sense the degree of deviation of the laundry
balance for 1 minutes.
C. After selecting the deviation degree of the laundry balance, it displays the data(in hex value) for
10 seconds.
9
1. Driving Compartment Test Mode
A. Hold down “1” and “2” keys simultaneously and then press POWER S/W on.
(Whole lamps turn on and display show “tE” or “tESt”.)
B. The driving compartment can be tested when you press “3” key right after entering
into the initial stage of the TEST MODE.
O
O
SWF-P14/SWF-P12/SWF-P10/SWF-P8
12 3