Installation
Installation
Alcove or closet installation
Minimum clearances for closet and alcove
installations:
Sides
1 in /
25 mm
Closet
front
1 in /
25 mm
Rear
5.9 in /
150 mm
Top
21 in /
533 mm
If the washer and dryer are installed
together, the closet front must have at least
a 72 in² (465 cm²) unobstructed air opening.
Your washer alone does not require a
specic air opening.
Recessed area
A
B B
A A
A 1 in (2.5 cm)
B 27.0 in (68.6 cm)
Side view - closet or conned area
A
B
C
D
E
A 21 in (53.3 cm)
B 1 in (2.5 cm)
C 29 7/16 in (74.4 cm)
D 5.9 in (15.0 cm)
E
Gap between end of water
valve and the wall
Case 1. Assemble supply
hose after installing : Over
4 in (10 cm).
Case 2. Assemble supply
hose before installing :
Over 3 in (8 cm).