38 _ Troubleshooting
Check Type
Check
Mode
Causes Remarks
Temperature
Sensor Check
TC1
TC2
- Thewashingheatersensorinthetubhasacheck.
(Contactcheckortemperaturesensorfault)
- Theconnectorisconnectedincorrectlyorisdisconnected.
- Ifthewaterlevelsensoroperateswithoutwaterbecausethe
waterisfrozenorforanyotherreasonandthetemperature
sensorengagedatthebottomtopreventoverheatingforthe
washingheaterdetectsatemperatureof100to150˚C,the
washingmachineturnstheinputpoweroff.
- Thedryingheatersensorinthetubhasacheck.
(Contactcheckortemperaturesensorfault)
Heatersensorfault
:Whentheconnector
isconnected
incorrectlyorhasa
wiredisconnectedor
contactcheck
TC4 -IPMtemperatureisabnormallyhigh.
Unbalance
Check
UB
- Aslaundrycausesthischeck,checkthelaundry.
- Findthereasonfortheunbalanceandsolveitasdirectedin
theusermanual.
Foaming
Detected
SUD
- Thisoccurswhentoomuchfoamingisdetected.Itisalso
displayedwhilefoamingisremoved.Whentheremovalis
nished,thenormalcycleproceeds.
“SUD”or“SUDS”isdisplayedwhentoomuchfoamingis
detectedand“End”isdisplayedwhentheremovalofthe
foamingisnished.
(Thisisoneofthenormaloperations.Itisacheckfor
preventingnon-sensingfaults.)
Mems PBA
Check Detected
8C1
- CheckdetectedintheMemsPBAordatacheckdetected.
Checkthewireconnections.
Replaceifnecessary.
1. Checkthewireconnections.
2. ReplacetheMemsPBA.
8C2
8C
System Check
SF1
- MicroControllerOperationFail. ReplaceAssyPCB.SF2
SF3