EasyManua.ls Logo

Samsung WF330ANW/XAA - Washer Connector Checks; Water Level and Hall Sensor Checks; Motor and Power Checks

Samsung WF330ANW/XAA
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Washer Connector Checks WF330
CN2
1 AC Pwr (Blk)
2 Power off Detection (Yel)
3 Door Lock Detection (Brn)
Water Level Sensor Check
Test 1 Test 2
Voltage: Connector CN 7 Pin 6 (Pink) and Pin 5
(Orange) And Connector CN 7 Pin 7 (Violet) and
Pin 5 (Orange)
Resistance: Connector CN 7 Pin 6 (Pink) and Pin 7
(Violet)
Operating voltage at no water in the
drum-2.5VDC
Operating Resistance (Power
off)
Pin 6 (Pink) and Pin 7 (Violet)
22- 24
Hall Sensor Check
Test 1 Test 2
Connector CN6 Pin 4 (Orange) and Pin 2 (Red)
additionally Pin 4 (Orange) and Pin 3 (blue)
Manually spin the drum to see the volt-
age change, Power On. 0Vdc or
3.75Vdc
N/A
Motor Check
Test 1 Test 2
Connector CN5 Pin 1 (Blue), Pin 2 (White) and Pin
3 (Red)
Power Off 11.5 across Pins 1-2,
Pins 1-3, & Pins 2-3
N/A
CN5
1 Motor Pwr U Phase (Blu)
2 Motor Pwr V Phase (Wht)
3 Motor Pwr W Phase (Red)
CN3
1 Door Close (Blk)
2 Door Open (Wht)
3 Drain Pump (Vio)
4 Boot Valve (Red)
5 Bleach Valve (Pnk)
6 Pre Valve (Yel)
7 Main Cold Valve (Blu)
8 Hot Valve (Org)
CN6 (Hall Sensor)
1 +5 vdc (Pnk)
2 Sensor Signal (Red)
3 Sensor Signal (Blu)
4 Ground (Org)
CN8
PCB Sub (Display)
CN7
4 Water Temp Thermistor (Wht)
5 Water Temp Thermistor Gnd. (Org)
6 Water Level Sensor (Pnk)
7 Water Level Sensor (Vio)
Main Relay
1 AC Pwr N (Blu)
2 AC Pwr (Wht)
Heater Relay
1 AC Pwr L1 (Blk)
2 AC Heater (Red)
CN1
1 Reactor (Gry)
2 Reactor (Gry)
CN4
1-3 Door Ck Sw (Org-Gry
3