ALIGNMENT AND ADJUSTMENTS
5
Denition of Quick Test Mode:
- CheckoperationofallLED’s(VerifyfaultyLED).
- Checkmodelandsoftwareversion.
- Checkdierentoperatingmodes(e.g.watervalve,motor,door,drainpump,etc.).
How to Enter:
- Plugintheunit.
- PressSoilKey,SpinKeyandPowerKeyatthesameTime.
Quick Test Mode:
1. AllLED’slightupanditsendsoutBeepSoundwhenit
entersintotheQuickTestMode.(Including7-Segment)
2. DisplayssoftwareversionforasecandClearEEprom.(Ex.If
S/WVersionis04,7-SegmentwilldisplayUd04)
3. Whentheversionisdisplayed,turntheJog-Dialsothat
theversiondisappears.Pressthefollowingkeystotestthe
variouscomponents.
-TempKey:WaterValveTest
-SpinKey:DoorLock/UnlockTest
-SoilKey:WaterHeaterTest
-Signal:DrainPumpTest
EEPROM Clear Check
Denition of EEPROM Clear Mode:
- EEPROMinitialization.
- Allcourse/optionsettingsaretoberesettodefault
valuesafterEEPROMinitialization.
- WhenServicearisesanditneedsPCBreplacement,
EEPROMshouldbereset.
How to Enter:
- Theunitneedstobeon.
- PressDelayStartKey,andPowerKeyatthesame
time.
Toavoidriskofelectricalshock,personalinjuryordeath;disconnectpowertowasher
beforeservicing,unlesstestingrequirespower.
WARNING
[BIGBANG]Technical_information-03207A-03_EN.indd 5 2013-7-16 17:15:04