EasyManua.ls Logo

Samsung WF42H5200AF - Page 22

Samsung WF42H5200AF
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20 _ Troubleshooting
Error Type For USA Causes Remarks
Power Error 9E1,9E2
- Checktheconsumer’spowerconditions.
: Makesuretochecktheoperatingvoltage.Connecta
testertotheinternalpowerterminalsduringtheBoilorDry
operationsandobservethewashingmachine’soperation
carefully.
: Checkthevoltages.
(Anerroroccurswhenunderorovervoltageissupplied.)
: Checkwhetheraplugreceptacleisused.
Whentheconnectingwireis1m,amomentarylowvoltage
maydropupto10V
- MainPBAfault(sometimes)
Communication
Error
AE
- ThesignalsbetweenthesubandmainPBAsarenotsensed
becauseofcommuicationerror.
- Checktheconnectorconnectionsbetweenthesubandmain
PBAscarefully.
→Checkforincorrectorlooseconnections,etc.
- RemovethesubPBAC/Panelandcheckforanyfaulty
soldering.
AE3
- ThesignalsbetweenTheDRModuleandmainPBAsarenot
sensedbecauseofcommuicationerror.
- CheckTheconnectorconnectionsbetweenTheDRModule
andmainPBAscarefully.
→Checkforincorrectorlooseconnections,etc.
- RemoveTheDRModuleandCheckforanyfaultysoldering.
AE4
- ThesignalsbetweenTheWIFIModuleandmainPBAsarenot
sensedbecauseofcommuicationerror.
- CheckTheconnectorconnectionsbetweenTheWIFIModule
andmainPBAscarefully.
→Checkforincorrectorlooseconnections,etc.
- RemovetheWIFIModuleandCheckforanyfaultysoldering.
AE5
- ThesignalsbetweenTheLCDModuleandmainPBAsarenot
sensedbecauseofcommuicationerror.
- CheckTheconnectorconnectionsbetweenTheLCDModule
andmainPBAscarefully.
→Checkforincorrectorlooseconnections,etc.
- RemoveTheLCDModuleandCheckforanyfaultysoldering.
AE6
-ThesignalsbetweentheInverterPBAandmainPBAarenot
sensedbecauseofcommunicationerror.
-CheckTheconnectorconnectionsbetweentheInverterPBA
andmainPBAcarefully.
→Checkforincorrectorlooseconnections,etc.
-RemovetheInverterPBAandCheckforanyfaultysoldering.
Switch Error
(Main Relay
Error)
bE2
- ThePowerbuttonispressedcontinually.
(formorethan12seconds).
- Aswitchisjammedorstuckduetobepressedunevenlydueto
deformationofthecontrolpanelorbutton.
- ThiserrormayoccurwhenthescrewsthatholdthesubPBAin
placearetightenedtoomuch.
- AbuttonotherthanthePowerbuttoniscontinuallypressed.
(formorethan30seconds).
- Deformationofaninternalplasticinjectionpart.
- AscrewforassemblingthesubPBAistightenedtoomuch.

Other manuals for Samsung WF42H5200AF

Related product manuals