Heater
HC
HC1
HC2
• Heaterfault
• AfaultofTheTemperature
sensoratthecenterofthe
dryheater
• Steamfunctionfault
• Freezinginthewinter
season
• Afaultofthetempsensorlocated
atbetweentheheaterterminals
-AnHCorHC1erroroccurs.
• Checkiftheoverheatingsensorof
thedryheater(orairwashheater)
isfaulty
• Ifitfaulty,Replaceit
-AnHC2erroroccurs.Checkthe
steamheater.Replaceiffaulty.
Washheater
WaterLeakage
LC
LC1
• Checkforanyleakage.
• ForeignmaterialintheDV
case
• Faultofahoseorincorrect
partengagementinthe
product
• Checkforanyleakageonthe
base,Hose,ValveandTub
connectionsandtakeanyrequired
action.
• Checkthedrainmotoroperation.
Replaceifitdoesnotoperate
normally
Checkforanyleakageonthebase,Hose,Valve
andTubconnections.
Overow OC
• Waterlevelsensorfault
• Freezinginthewinter
season
• Ifthewaterlevelsensorhasa
functionalerror,replaceit.
• Checkthehose.Thiserroroccurs
ifitistornorhasahole.
• Thiserroroccursifwaterisfrozen
inthewinterseason.Checkthe
methodtoremovefreezingand
followasdirected.
Checkthehoseconnectedtothewaterlevelsensor.
Checkwhetherthehoseisfolded,cut,or
damaged.
MAINPBA
DCvoltage
none • PBAmalfunction
• ChecktheDCvoltageoftheMain
PBA,replaceifwrongvoltage
output.
- Normal:Approx12V
- Normal:Approx5V
-
Temperature
Sensor
tC1
tC2
tC3
tC4
• Washingtemperature
sensorfault
• Drytemperaturesensor
fault
• Faultyandincorrect
connectionsofthedry
condensingsensor
• MainPCBfault
• Freezinginthewinter
season
• IPMtemperatureis
abnormallyhigh.
• Checktheconnectionsforthe
washingheatertemperature
sensorconnector.
• Ifthewashingheatertemperature
sensorhasafunctionalerror,
replaceit.
-AtC1erroroccurs.
• Checktheconnectionsforthe
dryheatertemperaturesensor
connector.
• Ifthedryheatertemperature
sensorhasafunctionalerror,
replaceit.
-AtC2erroroccurs.
-
Foaming
Detected
Sud • Toomuchfoaming
• Itisalsodisplayedwhilefoamingis
removed.
-Whentheremovalisnished,
thenormalcycleproceeds.“Sud”
or“SUdS”isdisplayedwhen
toomuchfoamingisdetected
and“End”isdisplayedwhen
theremovalofthefoamingis
nished.
(Thisisoneofthenormal
operations.Itisanoperationfor
preventingnon-sensingfaults.)
-