EasyManua.ls Logo

Samsung WW80TA046AX - Page 35

Samsung WW80TA046AX
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32 _ Troubleshooting
No. Information Type
Information
Code
Causes Corrective Actions
10 WaterLeakage
LC
LC1
- Heaterengagementfault.(outofplace)
- Theairhoseisoutofplaceandwaterleakageoccurs
duringthespincycle.
- Thetubbackatthesafetyboltsxingpartisbroken.
- Waterleakageoccursatthefrontwithfoaming
becauseoftoomuchdetergent.
- Waterleakageoccursbecausetheconnectinghoseto
thedetergentdrawerisconnectedincorrectly.
- Thedrainpumpltercoverisengagedincorrectly.
- Waterleakageoccursatthedrainhose.
- Theductcondensingholdingscrewsareworn.
- Thenozzle-diaphragmisengagedintheopposite
directionortherubberpackagingisomitted.
- Waterleakageoccursbecausethescrewsthat
holdthetubbackandfrontinplacearefastened
incorrectly.
- Theleakagesensorisfaulty.
•CheckWaterLeakage.
•DVCASEforeignmaterialoccurs.
•Leakageoftheproductinsidethe
hoseandpartsmoldedproblem.
11 OVER FLOW
OC
OF
- Waterissuppliedcontinuallybecausethewaterlevel
detectiondoesnotwork.
- Becausethedrainhoseiscloggedandthereisan
injectionerror(atanarrowsection),thewaterlevel
detectiondoesnotworkandwaterissupplied
continually.
- Waterissuppliedcontinuallybecauseoffreezingor
becausethereisforeignmaterialinthewatersupply
valve.
- Thismayoccurwhenthesensorisfaultyorthe
pressuretubeisblockedordamaged.
•Waterlevelsensorfault.
•Freezingbywinterseason.
12
Temperature
Sensor
TC1
- Thewashingheaterinthetubhasanerror.
(Contacterror,temperaturesensorfault)
- Theconnectorisconnectedincorrectlyoris
disconnected.
- Ifthewaterlevelsensoroperateswithoutwater
becausethewaterisfrozenorforanyotherreason
andthetemperaturesensorengagedatthebottom
topreventoverheatingforthewashingheaterdetects
atemperatureof100to150˚C,thewashingmachine
turnstheinputpoweroff.
•Washingtemperaturesensor
check.
•Drytemperaturesensorcheck
•Drycondensingtemperature
sensorcheck.
•ProblemscausedbythemainPCB
fault.
•Problemscausedbythefreezing
inwinter.
TC2
- Thetemperaturesensorfortheductassyfanhousing
isfaulty.(Asensorfaultsuchasaninternalshort-
circuitorwiredisconnection)
- Theconnectorisoutofplaceorhasacontacterror.
TC3
- Thisoccurswhentheductcondensingtemperature
sensor is open.
- Thisoccurswhentheductcondensingtemperature
sensorhasawiredisconnectedorisshort-circuited.
13 UNBALANCE UB
- Aslaundrycausesthiserror,checkthelaundry.
- Findthereasonfortheunbalanceandsolveitas
directedintheusermanual.
•Thisoccursbylaundry.

Other manuals for Samsung WW80TA046AX