4.AlignmentandTroubleshooting
ErrorCode
S6–3123
S6–3128
Errormessage
NetworkProblem:IPConict
802.1xNetworkError
Symptom
IPaddressconictswiththatofothersystem.
Troubleshootingmethod
1)Changethemachine’sIPaddress.
2)Checkthesetting-upfor802.1xconrmationserver.
ErrorCode
U1–2132
U1–2315
U1–2320
U1–2330
U1–2334
U1–2340
U1–234H
Errormessage
Error#U1-2132Turnoffthenon
Error#U1-2315Turnoffthenon
Error#U1-2320Turnoffthenon
Error#U1-2330Turnoffthenon
Error#U1-2334Turnoffthenon
Error#U1-2340Turnoffthenon
Error#U1-234HTurnoffthenon
Symptom
Thetemperaturecontroloffuserunitisabnormal.
Troubleshootingmethod
1)Checkiftheinputvoltageisnormal.
2)Turnthemachineoff.Removeandreinstallthefuserunit.BecarefulwhenconnectingtheAC-connectorand
Thermistorconnector.
3)Turnthemachineon.Istheerrormessageisdisappeared?
4)Checkthefollowings.Ifthefuserunithasanyproblem,replaceit.
a)Checkifthefuserconnectorisconnectedproperly.
b)Checkifthehalogenlampvoltageisnormal.
c)Checkifthethermistoriscontaminatedortwisted.
5)Iftheproblempersists,replacethemainboardorSMPSboard.