4.AlignmentandTroubleshooting
ErrorCode
A1-2112
A1-3612
Errormessage
Error#A1-2112Callforservice
Error#A1-3612Callforservice
Symptom
TheOPC/Devemotordoesnotoperate./TheOPC/Devemotorisoperatingbutisrecognizedasstopstatus.
Troubleshootingmethod
1)Turnthemachineoffthenon.Iftheerrorpersists,turnthemachineoffagain.
2)Removetherightcover.
3)CheckiftheconnectionbetweenmainboardandOPC/Devemotorarecorrect.
4)IftheconnectionisOK,replacetheOPC/Devemotor.
5)Iftheproblempersists,replacethemainboard.