EasyManuals Logo

Samwontech TEMP2500 Communications Manual

Default Icon
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
SAMWONTECH
1th Edition of TEMP2000_Series IM : Dec. 15. 2008 Page 29 / 63
7.3 RESERVATION Group
RESERVATION TEMP2500 hours of group identification, and book set, PROGRAM driver's start time and end time of
operation consists of related D-Register.
TIME setting and information D-Register
D-Reg. Symbol Description Read Write
D0202 NOW.YEAR Current YEAR installed in TEMP2500 ×
D0203 NOW.MONTH Current MONTH installed in TEMP2500 ×
D0204 NOW.DAY Current DAY installed in TEMP2500 ×
D0205 NOW.AMPM Current TIME-AM/PM installed in TEMP2500 ×
D0206 NOW.HOUR Current HOUR installed in TEMP2500 ×
D0207 NOW.MIN Current MN. installed in TEMP2500 ×
D0208 C.YEAR Current YEAR setting in TEMP2500 ×
D0209 C.MONTH Current MONTH setting in TEMP2500 ×
D0210 C.DAY Current DAY setting in TEMP2500 ×
D0211 C.AMPM Current TIME-AM/PM setting in TEMP2500 ×
D0212 C.HOUR Current HOUR setting in TEMP2500 ×
D0213 C.MIN Current MN. setting in TEMP2500 ×
D0214 R.YEAR YEAR setting for RESERVE Operation
D0215 R.MONTH MONTH setting for RESERVE Operation
D0216 R.DAY DAY setting for RESERVE Operation
D0217 R.AMPM TIME-AM/PM setting for RESERVE Operation
D0218 R.HOUR HOUR setting for RESERVE Operation
D0219 R.MIN MIN. setting for RESERVE Operation
RESERVE Operation
D-Reg. Symbol Operation Setting Description
OFF 0 Release RESERVE Oper.
D0200 RESERVE
ON 1 Set RESERVE Oper.
PROGRAM Start time and end time running
D-Reg. Symbol Description
D0260 CH1_TIME_VALID Show start time and end time (0: Normal, 1:---.-)
D0261 CH1_START_YEAR Setting start time (Year)
D0262 CH1_START_MON Setting start time (Month)
D0263 CH1_START_DAY Setting start time (Day)
D0264 CH1_START_HOUR Setting start time (Hour)
D0265 CH1_START_MIN Setting start time (Min)
D0266 CH1_END_YEAR Setting end time (Year)
D0267 CH1_END_MON Setting end time (Month)
D0268 CH1_END_DAY Setting end time (Day)
D0269 CH1_END_HOUR Setting end time (Hour)
D0270 CH1_END_MIN Setting end time (Min)

Other manuals for Samwontech TEMP2500