200-2156
Revision F
Operator Manual
Manuel de l’opérateur
Manual del operador
Two-Stage, Belt-Drive, Gas Air Compressors
Á deux étapes, actionnement pour courroie, compresseurs d’air essences
De dos etapas, accionamiento por correa, compresores de aire gasolinas
200-2156_Rev. F_11-12
WARNING: Read and understand all safety precautions in this manual before operating. Failure to comply with
instructions in this manual could result in personal injury, property damage, and/or voiding of your warranty. The
manufacturer WILL NOT be liable for any damage because of failure to follow these instructions.
AVERTISSEMENT : Lire et s’assurer de bien comprendre toutes les consignes de sécurité du présent manuel
avant d’utiliser l’outil. Toute dérogation aux instructions contenues dans ce manuel peut entraîner l’annulation de la
garantie, causer des blessures et/ou des dommages matériels. Le fabricant NE SAURA être tenu responsable de
dommages résultant de l’inobservation de ces instructions.
ADVERTENCIA: Lea y comprenda todas las precauciones de seguridad contenidas en este manual antes de
utilizar esta herramienta. El no cumplir con las instrucciones de este manual podría dar como resultado la anulación
de su garantía, lesiones personales y/o daños a la propiedad. El fabricante NO SERA responsable de cualquier
daño debido a no acatar estas instrucciones.
Product style and configuration may vary.
Le style et la configuration du produit peuvent varier.
El estilo y la configuración del producto puede variar.

Table of Contents

Questions and Answers

  • M
    Mrs. Jennifer Lawson MDAug 8, 2025
    Why is my Sanborn Mfg 200-2156 Air Compressor losing pressure?
    • D
      Daniel MendozaAug 8, 2025
      Low discharge pressure in your Sanborn Mfg Air Compressor can occur due to several reasons. Air leaks in the fittings or connections may be the cause; try tightening or replacing any leaking components, being careful not to overtighten. A restricted air intake could also be the problem, so cleaning or replacing the air filter element(s) is recommended. Leaking valves, blown gaskets, or worn piston rings or cylinder may also cause this issue. In these cases, you should contact an authorized service center.
  • H
    Hannah BakerAug 12, 2025
    What to do if my Sanborn Mfg 200-2156 Air Compressor is overheating?
    • L
      Laura MillsAug 12, 2025
      If your Sanborn Mfg Air Compressor is overheating, several factors could be the cause. First, check for poor ventilation. Relocate the compressor to an area with cool, dry, well-circulated air, ensuring it's at least 12 inches away from the nearest wall. Second, inspect for dirty cooling surfaces and clean them thoroughly. Finally, restricted air passages may be the problem, in which case you should replace the transfer tubes and/or unloader.
  • I
    imartinAug 16, 2025
    How to fix oil in the discharge air of my Sanborn Mfg 200-2156 Air Compressor?
    • B
      Beth LeeAug 16, 2025
      If you notice oil in the discharge air of your Sanborn Mfg Air Compressor, it could be due to several reasons. Worn piston rings or cylinder can cause this issue, in which case you should contact an authorized service center. Another potential cause is a restricted air intake; try cleaning or replacing the air filter element(s). Also, check the oil level; if it's too high, reduce it to the proper level and use synthetic blend, non-detergent air compressor oil.
  • A
    Amanda BlakeAug 20, 2025
    What causes my Sanborn Mfg 200-2156 pump to knock?
    • J
      Jackie JacksonAug 20, 2025
      A knocking sound in your Sanborn Mfg Air Compressor pump can be attributed to a few issues. Check if the engine pulley or compressor flywheel is loose and retighten them, ensuring proper alignment. Also, verify that the oil level in the pump crankcase is adequate and keep it at the correct level at all times. If there's excessive carbon on the valves or top of the piston, you should contact an authorized service center.
  • C
    Christina CalderonAug 25, 2025
    Why does my Sanborn Mfg Air Compressor belt wear out so quickly?
    • J
      jason20Aug 26, 2025
      Excessive belt wear on your Sanborn Mfg Air Compressor can stem from a few causes. Ensure the pulley is in alignment with the compressor flywheel. Also, check the belt tension and readjust if it's not correct. Finally, if the pulley wobbles, replace it and inspect for damage to the crankshaft or flywheel.
  • D
    Denise StoutAug 29, 2025
    What causes excessive unloader cycling in my Sanborn Mfg 200-2156 Air Compressor?
    • H
      hernandezjoshuaAug 29, 2025
      Excessive unloader cycling in your Sanborn Mfg Air Compressor is often due to air leaks in the piping. To resolve this, tighten or replace any leaking fittings or connections, but be careful not to overtighten them.
  • L
    Linda WardSep 2, 2025
    What to do if Sanborn Mfg 200-2156 won’t start in cold weather?
    • D
      Dr. Jennifer YoungSep 2, 2025
      If your Sanborn Mfg Air Compressor won’t start in cold temperatures, it could be due to several reasons. Make sure the compressor is winterized, see cold weather preparation. If the engine is flooded, remove the spark plug, dry it, and reinstall it. Also, the compressor might be too cold; try moving it to a warmer location.