EasyManua.ls Logo

Sanyo 26KHS72R User Manual

Sanyo 26KHS72R
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
System: 26KHS72R Indoor/Outdoor: KHS2672R/CH2672R
Wall Mounted Heat Pump
Power V/PH/Hz 230/208/1/60
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
Refrigerant
Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max (ft.)
Lift Difference, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
Outdoor Unit
Weight
Net
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
Heating
Total Capacity
HSPF
(A) 15-30 Indoor-Outdoor
(A) 15-30 Indoor-Outdoor
General Data (at 230V)
1
(A) 12.9-17.5
Propeller
18-7/64-1
DC Motor
(RPM) 8 - 800
(W) 1 - 90
14.9
(Pints/H) 8.1
(BTU/H) 25,200 (9,500-25,200)
(BTU/H) 14,790
(BTU/H) 10,410
(Uncrated) 12-63/64 x 44-7/8 x 8-31/32
(W) 2,840/2,840
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffeled
(in.) 3/8”
4.19
Split System Submittal Data
Electric Expansion Valve
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
1 - 15.9
(sq.ft.) 7.26
(lbs.) 40 128
(A) 15.3/16.9
(in. O.D. Discharge) 3/8”
(in. O.D. Suction) 5/8”
DC Rotary Inverter
(High) 1765
(A) 13.8
R410A
(in.) H x W x D
(Crated) 15-11/32 x 47-27/32 x 11-17/32
Indoor Outdoor
(cu.ft.) 4.9 13.0
Indoor Outdoor
(lbs.) 44 148
(dB-A) 49
Cross Flow
3-15/16 L33-15/64 - 1
3 & Auto
(RPM, High) 4 - 1224
(W) 1 - 29
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riffeled
(in.) 9/32”
2 - 24.1
(sq.ft.) 2.57
(HI/Med/Lo) 559/475/390
(A) 0.31
(in.) 1-1/4”
(Hi) (dB-A) 48
Flare
165
50 (outdoor lower), 100 (outdoor higher)
(Uncrated) 30-23/32 x 37 x 13-3/8
(Crated) 34-31/32 x 39-31/32 x 16-3/32
10.2
(BTU/H) 29,200 (8,000-29,200)
Question and Answer IconNeed help?

Do you have a question about the Sanyo 26KHS72R and is the answer not in the manual?

Sanyo 26KHS72R Specifications

General IconGeneral
BrandSanyo
Model26KHS72R
CategoryAir Conditioner
LanguageEnglish

Summary

General Unit Specifications

Power and Electrical Ratings

Electrical specifications including voltage, circuit ampacity, and maximum fuse size for the system.

Compressor and Refrigerant Details

Information on the compressor type, running amps, refrigerant used, charge, and line set specifications.

Unit Dimensions and Weight

Physical dimensions and weight for both indoor and outdoor units, including crated and uncrated states.

Outdoor Unit Specifications

Outdoor Unit Fan and Coil

Details on the outdoor unit's fan type, size, speeds, and coil construction.

Outdoor Unit Performance Metrics

Airflow (CFM), full load amperage, and sound rating for the outdoor unit.

Indoor Unit Specifications

Indoor Unit Fan and Coil

Details on the indoor unit's fan type, size, speeds, and coil construction.

Indoor Unit Performance Metrics

Airflow (CFM), full load amperage, sound rating, and drain connection size for the indoor unit.

Performance Data and Operating Ranges

Cooling Performance Data

Cooling capacity, sensible/latent capacity, SEER, dehumidification, and amperage under standard conditions.

Heating Performance Data

Heating capacity and HSPF rating for the unit.

Operating Range and Features

Indoor and outdoor air temperature operating limits for cooling and heating modes.

Unit Dimensions and Installation

Detailed Unit Dimensions

Specific measurements and diagrams showing the physical size of the indoor and outdoor units.

Installation and Connection Points

Diagrams illustrating anchor bolt locations, refrigerant tube joints, and drain hose connection.

Related product manuals