EasyManua.ls Logo

Sanyo C0971 - Performance Data - KS1271;CL1271 Cooling Curves; Cooling Characteristics Pressure-Current Graph

Sanyo C0971
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Indoor Unit KS1271 Outdoor Unit CL1271
Cooling Characteristics
Low pressure at wide tube service valve
psig(MPaG)
Operating current (A)
173
(1.2)
131
(0.9)
145
(1.0)
159
(1.1)
Outdoor fan speed
HighLow
10
12
14
15
9
8
11
13
Outdoor fan speed
HighLow
Outdoor fan speed
HighLow
80
°F(
27
°C)
75
°F(
24
°C)
Indoor Air Temp.86
°F(30°C)
Indoor Air Temp.86
°F(
30
°C)
75
°F(
24
°C)
80
°F(
27
°C)
80
°F(
27
°C)
75
°F(
24
°C)
Indoor Air Temp.86
°F(
30
°C)
68.0(20)
64.4(18)
60.8(16)
57.2(14)
53.6(12)
50.0(10)
46.4(8)
42.8(6)
Indoor discharge air temperature °F(°C)
77
(25)
86
(30)
95
(35)
104
(40)
77
(25)
86
(30)
95
(35)
104
(40)
Outdoor inlet air D.B. temp.°F(°C)
Outdoor inlet air D.B. temp.°F(°C)
Outdoor inlet air D.B. temp.°F(°C)
77
(25)
86
(30)
95
(35)
104
(40)
Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value.
:Points of rating condition
Black dots in above charts indicate the following rating conditions.
NOTE
Cooling: Indoor air temperature 80 °F D.B. / 67 °F W.B.
Outdoor air temperature 95 °F D.B.
23

Table of Contents

Related product manuals