1.
: Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.
: Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.
2.
3. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air
Prevention Protection during heating operation into account. For this reason, the value may vary
from the actual heating characteristics.
RATING CAPACITY: 20,400 BTU/h AIR FLOW RATE: 383 CFM
OUTDOOR INDOOR
ENT. TEMP.
o
F (
o
C) AMBIENT TEMP.
o
F (
o
C)
W.B. 60 65 70 75 80
(15.6) (18.3) (21.1) (23.9) (26.7)
0 (-17.8) TH 11,350 11,400 11,440 11,480 11,510
CI
1.35 1.41 1.47 1.53 1.59
3 (-16.1) TH 11,720 11,770 11,820 11,850 11,890
CI 1.37 1.44 1.50 1.56 1.62
8 (-13.3) TH 12,600 12,650 12,700 12,750 12,780
CI
1.43 1.50 1.57 1.64 1.71
13 (-10.6) TH 13,520 13,580 13,630 13,670 13,710
CI 1.50 1.57 1.65 1.72 1.80
18 (-7.8) TH 14,540 14,600 14,650 14,700 14,730
CI
1.57 1.65 1.74 1.82 1.90
23 (-5.0) TH 15,610 15,670 15,730 15,770 15,810
CI 1.65 1.74 1.83 1.92 2.00
28 (-2.2) TH 16,730 16,800 16,850 16,890 16,930
CI 1.74 1.83 1.93 2.02 2.12
33 (0.6) TH 17,900 17,960 18,010 18,060 18,090
CI 1.83 1.93 2.04 2.14 2.24
38 (3.3) TH 19,050 19,120 19,170 19,210 19,240
CI
1.92 2.03 2.14 2.25 2.36
43 (6.1) TH 20,290 20,350 # 20,400 20,440 20,460
CI 2.02 2.14 2.26 2.38 2.50
48 (8.9) TH 21,550 21,610 21,650 21,690 21,700
CI 2.13 2.26 2.39 2.52 2.64
53 (11.7) TH 22,830 22,890 22,930 22,950 22,960
CI 2.39 2.53 2.53 2.66 2.80
58 (14.4) TH 24,080 24,130 24,170 24,180 24,190
CI 2.37 2.52 2.67 2.81 2.96
63 (17.2) TH 25,390 25,430 25,450 25,460 25,460
CI 2.51 2.67 2.82 2.98 3.13
65 (18.3) TH 25,900 25,940 25,960 25,970 25,950
CI 2.57 2.73 2.89 3.05 3.21