Sanyo CM2472A - 5. Wiring Instructions; 5-5. Outdoor Unit Wiring Instructions; Grounding and Cable Labeling

Sanyo CM2472A
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
1
2
3
1
2
3
1
2
3
1
2
3
Indoor unit B
Indoor unit A
Ground
Power:
Single-phase,
230/208VAC 60HZ
Power breaker
(not provided)
Outdoor unit
Terminal board
Label A
Inter-unit cables
#14 (not provided)
Terminal board
Inter-unit cables
#14 (not provided)
Terminal board
Label B
Label C
Inter-unit cables
#14 (not provided)
Inter-unit cables
#14 (not provided)
Terminal board
Terminal board
Label D
A
B
C
D
Power cable (not provided)
(#12: Less than 85 ft.)
Be sure to perform grounding.
Attach a ground wire to either the
outdoor unit or indoor unit.
If there is a grounding terminal
inside the room, use the grounding
screw inside the indoor unit.
Be sure to apply the provided labels to both
ends of the inter-unit cables to prevent mis-
wiring. The units will not function if the wiring
connections are incorrect.
A is the indoor unit with
refrigerant tubing that is
connected to service valve
A (bottom) of the outdoor unit.
refrigerant tubing that is
connected to service valve B
(second from the bottom) of
the outdoor unit.
B is the indoor unit with
Indoor unit C
refrigerant tubing that is
connected to service valve
C (third from the bottom)
of the outdoor unit.
C is the indoor unit with
Indoor unit D
refrigerant tubing that is
connected to service valve
D (top) of the outdoor unit.
D is the indoor unit with
1 2
1 2 3 4 5 6 7 8 9 10 11 12
Power supply
(conduit)
Inter Unit
(conduit)
Inter Unit
(conduit)
# ... AWG (American Wire Gauge)
5-5. Wiring Instructions for the Outdoor Unit
G Be sure to correctly align inter-unit cables A, B, C and D.
G Use a dedicated air conditioner circuit for power.
G To make connections to the outdoor unit, remove the inspection panel and tubing panel.
G Do not bring the inter-unit cables or power cable into contact with tubing or service valves.
G Use outdoor unit cable fasteners and fasten the inter-unit cables at the location where the cables are double-
sheathed.
G Arrange the wiring so that the inter-unit cables are contained in the inspection panel and tubing panel, as shown in
Fig. 31.