EasyManua.ls Logo

Sanyo CM2472A - < Combinations of operatable indoor units >; CM2472, A (230 V) Unit Combinations; Concurrent Operation Prohibition

Sanyo CM2472A
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE
< Combinations of operatable indoor units >
CM1972, A
(Rated cooling capacity at 230V: 19700 BTU/h)
Voltage Rating : 230V 60Hz
9000 : XMS0972
11900 : XMS1272
17500 : XS1872
-2-
The table lists the ceiling-mounted type of indoor units as representative models.
When one or more ceiling-mounted type indoor units are operated concurrently with one or more
wall-mounted type indoor units, the performance specifications of the ceiling-mounted type models
will decrease by 10% from those listed in the wall-mounted type combination table.
Table 1
Indoor Unit Combination
Indoor Unit Capacity (BTU/h)
COOLING
Room
A
Room
B
Room
C
Total Performance
Capacity ( Min. Max. )
Single-room
Operation
)009010074(000900090009=0009
)002210015(009110091100911=00911
)005710045(005710057100571=00571
2-room
Operation
9000 + 9000 = 18000 8500 8500 17000 ( 6800 17000 )
9000 + 11900 = 20900 7709 10191 17900 ( 7100 17900 )
9000 + 17500 = 26500 6148 11952 18100 ( 7100 18100 )
11900 + 11900 = 23800 8950 8950 17900 ( 6800 17900 )
11900 + 17500 = 29400 7325 10775 18100 ( 7100 18100 )
3-room
Operation
9000 + 9000 + 9000 = 27000 6033 6033 6033 18100 ( 9800 18100 )
9000 + 9000 + 11900 = 29900 5449 5449 7203 18100 ( 9800 18100 )
9000 + 11900 + 11900 = 32800 4967 6566 6566 18100 ( 9800 18100 )
11900 + 11900 + 11900 = 35700 6100 6100 6100 18300 ( 9800 18300 )