Cooling Characteristics
(RH : 46%, Indoor fan speed : High fan)
(230V, 60Hz)
(1) Low pressure performance chart
(2) Operating current performance chart
(3) Indoor discharge air performance chart
• This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on
the indoor unit type.
• Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value.
(In this case, be sure to stop all the indoor units where performance is not being checked.)
• The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary.
NOTE
Low pressure at wide tube service valve
psig (MPaG)
Outdoor air temperature °F (°C)
Lo fanHi fan
Operating current (A)
Outdoor air temperature °F (°C)
5
6
4
3
Lo fanHi fan
Indoor discharge air temperature °F (°C)
Outdoor air temperature °F (°C)
Lo fanHi fan
Outdoor Unit CM1972A Indoor Unit KMS0972 ×
1
HH fan
HH fan
HH fan
174
(1.2)
188
(1.3)
160
(1.1)
146
(1.0)
77
(25)
86
(30)
95
(35)
104
(40)
46.4( 8)
68.0(20)
64.4(18)
60.8(16)
57.2(14)
53.6(12)
50.0(10)
77
(25)
86
(30)
95
(35)
104
(40)
77
(25)
86
(30)
95
(35)
104
(40)
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)
Indoor air temp. 86°F (30°C)
80°F (27°C)
75°F (24°C)
25