CHDZ14053
Heat Recovery: 12 tons VRF Outdoor Unit
Capacities
Cooling: Btu/h
Power Input: KW
Heating: Btu/h
Power Input: KW
Cooling Mode Nominal Conditions
Indoor: °F DB/°F WB
Outdoor: °F DB
Pipe Length (feet):
Level Difference (feet):
Heating Mode Nominal Conditions
Indoor: °F DB
Outdoor: °F DB/ °F WB
Pipe Length (feet):
Level Difference (feet):
Operating Range
Cooling: °F DB:
Heating: °F DB:
Compressor
Quantity/Type:
Capacity Control Range:
Fan
Quantity/Type:
Fan Motor Output (KW):
Power Supply
V/PH/Hz.
Minimum circuit Amps (MCA): Amps
Max. Overcurrent Protection (MOCP):
Weight (lbs):
Refrigerant:
Coil
Coil Face Area (sq. ft.):
Number of Rows:
Protection Devices
High Pressure Switch:
Overcurrent (CT Method):
Crankcase Heaters (W):
External Finish:
153,600
13.3
170,600
13.2
80/67
95
25
0
70
47/43
25
0
Yes
Yes
25 + 32 x 2
208-230 / 3 / 60
59
70
1 Propeller
0.7
14 to 109
-4 to 59
1 Inverter driven rotary & 2 fi xed speed scroll
10-100%
789
410A
Electrostatic Powder Coating
22.5
ECO-i
Submittal Data
4
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit #:
Drawing #:
Compressor Warranty: 6 Years
Parts Warranty: 1 Year
Coil Coated to Protect Against Corrosion
Salt Protection also avilable
Print Form
Question and Answer IconNeed help?

Do you have a question about the Sanyo ECO-i CHDZ14053 and is the answer not in the manual?

Sanyo ECO-i CHDZ14053 Specifications

General IconGeneral
BrandSanyo
ModelECO-i CHDZ14053
CategoryAir Conditioner
LanguageEnglish

Summary

Unit Specifications Overview

Capacities, Power, and Fan Details

Details cooling and heating capacities, power inputs, fan quantity/type, and motor output.

Nominal Operating Conditions

Specifies indoor and outdoor conditions for cooling and heating modes, including pipe length.

Operating Range and Compressor Information

Defines operational temperature limits, compressor type, and capacity control range.

Unit Features, Protection, and Finish

Includes warranties, coil protection, safety devices, and external finish description.

Unit Dimensions and Connections

Top and Front View Dimensions

Provides overall dimensions and key measurements for top and front views of the unit.

Side View and Enlarged Details

Shows side view, enlarged connection details, and mounting surface information.

Refrigerant Tube Connection Sizes

Details connection sizes for refrigerant tubes based on unit horsepower.

Connection Ports and Knock-out Holes

Identifies various ports for refrigerant, tubing, electrical wiring, and pressure gauges.