9
(H) Receiving 999 kHz
(I) AM Local Mode
(J) S. Meter Adj. Mode
(K) The Moment TP ON
(L) Change the Display while TP ON
(M) The Moment AF ON
(N) Change the Display while AF ON
(O) The Moment 107.1 MHz Receiving
(P)
Change the Display while 107.1 MHz Receiving
Fig. 10
7. Press the t
TA
button in the step 1, the unit enters the S meter adjustment mode. Rotate the R208 on Main PCB to adjust
the LCD until the 0.95 lights up. Fig. 10 (J)
8. e
POWER
OFF and ON. Release the test mode.
9. e
POWER
OFF and press the y
PRESET 5
.
SG 98.1 MHz, MOD. 75kHz, INT MOD. EXT, att 66dBµ
RDS 1.0%, MOD. 30% 1 kHz, MONO, RDS ON, TP ON, SK OFF, BK OFF.
10. Confirm the
TP
indicator on the LCD lights up.
Fig. 10 (K) (L) soon. So RDS ON Sensitivity is OK.
11. Press the q
PRESET 1
button for more than 2 seconds. (Memorize the RDS).
12. Press the t
TA
button for more than 2 seconds and confirm the
AF
indicator on the LCD lights up. Fig. 10 (M) (N) soon.
SG 107.1 MHz, MOD. 75kHz, INT MOD. EXT, att 66dBµ
RDS 1.6%, MOD. 30% 1 kHz, MONO, RDS ON, TP ON, SK OFF, BK OFF.
13. Press the q
PRESET 1
button. Confirm the receiving 107.1 MHz automatically. So the LCD indicator displays Fig. 10 (O)
(P).