EasyManua.ls Logo

Sanyo HEC-DR7700 - Massaging (Automatic Course); Turn the sole warmer on or off.; Adjust the positions of the back rest and the foot rest.

Sanyo HEC-DR7700
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
19
-
HEC-DR7700
Replacement Procedure
(5) Replacement of Reclining Motor
1, Take off the arm rest and cover(arm rest
lower). Photo-1,2
2, Take off the cover (under front ). Photo-3
3, Disconnect each cord processing and cords.
4, Lay down the massager with its left side
facing downward. Photo-8
5, Each reclining motor (set) is fixed at two
places on both ends. Therefore, remove
E rings on both ends and pull out fixing pins.
Photo-9
(6) Replacement of Power Switch
and Current Fuse
1, Take off the cover (arm rest lower) right.
Photo-2
2, Remove each cord processing and
disconnect the cords.
3, Remove two case (switch box) set screws
and take off the case (switch box).
Photo-10
4, Open a fuse case of current fuses and take
out a current fuse. Photo-11
5, Remove two switch holder set screws and
take off a switch holder.
Photo-11
6, Remove a switch fixing screw and take off
the POWER switch. Photo-11
Switch holder set screws
Case set screws
POWER switch
Connector (sensor A)
Connector (remote control A)
Photo-10
Photo-11
Case (switch box)
Current fuse
Power cord
Photo-8
Reclining motor
(foot rest)
Reclining motor
(back rest)
Reclining motor (seat)
E rings & fixing pins
Photo-9
Reclining motor (back rest)
Reclining motor (foot rest)
E rings & fixing pins
Reclining motor (seat)
E rings & fixing pins