18
9. ELECTRICAL DATA
Electrical Characteristics
Indoor unit KHS1232
Outdoor unit CH1232
Cooling
Heating
Indoor Unit Outdoor Unit Complete Unit
Compressor
Rating Condition
Fan Motor
Back-up
Fan Motor Without With
Without With
Heater
Heater* Heater*
Heater* Heater*
ab c d e (a+c+d) (a+b+c+e)
Performance
230V
A 0.18 6.5 0.42 4.5 4.6 5.1 11.7
at 60Hz
W 33 1,500 94 1,043 1,043 1,170 2,670
Single phase
208V
A 0.17 5.9 0.39 4.84 5.24 5.4 11.7
W 29 1,227 79 1,012 1,012 1,120 2,347
Rating Condition
Indoor Unit Outdoor Unit
Complete Unit
Fan Motor Fan Motor Compressor
abc
(a+b+c)
Performance
230V
A 0.18 0.42 4.9 5.5
at 60 Hz
W 33 94 1,083 1,210
Single phase
208V
A 0.17 0.39 5.34 5.9
W 29 79 1,072 1,180
* Heater means back-up heater built into the indoor unit.
Cooling
Rating conditions: Indoor air temperature 80°F DB/ 67°F WB
Outdoor air temperature 95°F DB
Heating
Rating conditions: Indoor air temperature 70°F DB
Outdoor air temperature 47°F DB/43°F WB
NOTE